Welcome to Btrworlds.com, Join Free | Sign In
 
Home > Product Directory > Free Cooling Rooftop Packaged
Btrworlds can provide most competitive 20 Ton Free Cooling Packaged Rooftop Air Conditioner,
20 Ton Free Cooling Packaged Rooftop Air Conditioner

Like this Product? Add to Product Favorites

20 Ton Free Cooling Packaged Rooftop Air Conditioner

Unit Price: FOB,CFR,CIF   |  Get Latest Price

Model No.: RTU12~RTU300

Min. Order: 1 Set/Sets

Payment Type: L/C,T/T,Western Union

Transportation: Ocean

Productivity: 6000PCS/Year

Packaging: Plywood Casing or standard package suitable for sea and air transport

Delivery Time: 30 Days

Place of Origin: China

Brand: Amrta or OEM

Supply Ability: 500PCS/Month

Mr.Richard Lee Administrative

Business type:Manufacturer

Tel:86-0531-88901036

View Contact Details

If you do not find the desired product Please Post Sourcing Request
  • Product Catalog
  • Company List

Product Description

Free cooling also called ecomonimzer, which is energy saving, based on air conditions, can provide outside air to cool the space. Amrta Air Conditioner with a cooling capacity of up to 65kW sold in Australia or New Zealand must now comply with the Minimum Energy Performance Standards (MEPS), as set out in Australian and New Zealand Standards. Amrta Rooftop Packaged Unit exceed MEPS requirements, in line with Amrta's commitment to providing energy efficient, quiet, simple to use and reliable Air Conditioning Solutions.


Characteristics

01.Structure. Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Direct expansion coils with condensate drain tray.
02. Hermetic compressor. High efficiency scroll compressor for the whole range, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers. Ripple type acoustic insulation for compressor section, and thermal insulation for coil and fan section, low noise.
03.Centrifugal fan. Forward curve centrifugal fans for air treatment section and axial fans for condensation section. Front, side and underside air discharge of the treatment unit. High external pressure, long air supply distance.
04. Electric panel. Electric panel consists of breakers and contactors for compressors and fan motors, phase sequence relay and other necessary protection devices for the main components.
05. Easy operation line controller
Cooling/Heating/Auto
Error indication
Timing on/off
06. Optional

Economizer with fresh, return air dampers and fresh air hood

Free cooling function for low ambient temperature

Low ambient control device for operation of outdoor units at ambient temperatures from less than 20°C down to -10°C
BMS devices
T3 (Tropical climate)
Roof curb
Metal/aluminum filter
100% heat recovery
Evaporating section: double skin with 50mm polyurethane foam
Optional water heating coil
Metal or plastic mesh on condenser coil
Optional supply/return air configurations
Upgraded plug fan

G4 filter, plate and bag filter


Economizer and Free Cooling ( Option )

It is one of the most important features of this rooftop as it maximise seasonal efficiency by reducing the use of thermodynamic cooling in mid season.

Thermodynamic cooling can be replaced by Free Cooling when outdoor temperature is below the building set point saving up to 15% on annual energy consumption.
Rooftop packaged unit is supplied with economizer and fresh air hood to improve comfort through better fresh air management and allow energy savings with free cooling.
Exhaust air
● Gravity exhaust damper
Gravity exhaust damper Installed with economizer assembly, gravity exhaust damper relief pressure when outside air is being introduced in the system. It is a cheap and smart way to avoid over pressure in a building.
● Power exhaust fans
Installed with economizer assembly, it provides exhaust air pressure relief when high levels of fresh air are being introduced in the system.

Interlocked to run when return air dampers are being closed and supply air blower is in operation. The extraction fans run when outdoor air dampers are at least 50% open (adjustable). It is also overload protected. A gravity exhaust damper is supplied with this option to prevent air from entering the unit during shutdown. The power exhaust fans have been size to exhaust 50% of the nominal air flow of the unit.

Free Cooling Packaged Rooftop


Technical Data

Model 

RTU45

RTU50

RTU60

RTU75

RTU90

RTU105

Cooling capacity

kW

44.5

50

60

70

90

105

Heating capacity

kW

48.7

54.3

64

75.4

96.2

113.2

Power supply

  380V / 3Ph / 50HZA

Cooling power input

kW

17

19.5

22.8

26.7

32.9

39.7

Heating power input

kW

15.6

18

21

24.8

30.4

36.7

Start current

A

168

186

175

199

197

266

Working current in cooling

A

31.7

35.6

39.9

48.3

61

70.6

Working current in heating

A

29.9

33.5

37.5

45.4

57.3

66.3

Throttle methods

Thermal expansion valve

Circuits

2

2

2

2

3

3

Refrigerant

R410A

Compressor

Type

Scroll type        380V / 3Ph / 50HZA

Qty

2

2

2

2

3

3

Condenser side

Condenser

Type

Al+copper tube

Axial fan

Qty

1

1

1

1

2

2

Drive

Direct drive

Motor power

kW

0.25

0.37

0.37

0.55

0.75

0.75

Air flow

m/h

4600

7800

7800

9000

12600

12600

Evaporator side

Evaporator

Type

Al+copper tube

Centrifugal fan

Qty

1

1

1

1

1

1

Motor power

kW

3

3

4

4

5.5

5.5

Air flow

m/h

7600

8500

10900

12500

16000

19500

Drive

Direct drive

Belt drive

External static pressure(Pa)

250

250

300

300

300

300

Filter

Aluminum frame filter G3

Noise level dB(A)

73

73

73

75

74

75

Dimension

L

mm

2268

2268

2298

2298

2878

2878

W

mm

1440

1440

1650

1650

2140

2270

H

mm

1167

1167

1400

1400

1964

1964

Weight

kg

750

770

830

860

1160

1350

* Performance values refer to the following conditions:
Cooling: room air temperature 27.0°C DB RH 50%, ambient air temperature 35°C;
Heating: room air temperature 20.0°C DB, ambient air temperature 7°C DB / 6°C WB.
** Noise level measured by adopting average value in the noise lab with background noise of 25 dB(A), at a distance of 1.5m high fan speed.

Siemens PLC Free Cooling Rooftop UnitEconomizer Packaged Rooftop

http://www.amrtaac.com

AMRTA specialize in commercial air conditioner and cooling system solutions for commercial and industrial use. Our products cover water chiller, Rooftop packaged unit, heat pump and fan coil units etc.

We AMRTA constantly build upon our history of proven innovation with new products and services that improve global comfort and efficiency.

AMRTA offer extraordinarily innovative and exceptionally reliable service, so why would you install anything but AMRTA? Please check our website: amrta.com.cn.

Basic Information

  • Company Name:

    Jinan Amrta Air Conditioning Co.,Ltd

  • Representative:

    Haiyan Wang

  • Business Type:

    Manufacturer

  • Product/Service:

    Water Chiller , Air Conditioner , Rooftop Packaged Unit , Heat Pump System , Fan Coil , Air Handling Systems

  • No. of Total Employees:

    51~100

  • Capital (Million US $):

    US$5 Million

  • Year Established:

    2012

  • Certificate:

    Manufacturer

  • Company Address:

    No.13788 Century Road, Jinna, Shandong, P.R.China

Factory Information

  • No. of Production Lines:

    5

  • No. of R&D Staff:

    5 -10 People

  • No. of QC Staff:

    5 -10 People

  • OEM Services Provided:

    yes

  • Factory Size (Sq.meters):

    10,000-30,000 square meters

  • Factory Location:

    No. 13788 Century Road, Jinna, Shandong, P.R.China

Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters
Related Keywords
Recommended Products